NVIDIA HGX H200

Eight Hopper GPUs with the larger memory. Air cooled, one node per rack in an existing hall.

  • 8 GPUs per node
  • 1.1 TB GPU memory
  • Air
  • Available Q1 2027

Configurations

Pick the footprint that fits. Every one is sold on the same contract.

8 GPUsOne node
The smallest unit. One node per rack in an existing Santiago hall.
16 to 248 GPUsTwo to thirty-one nodes
One fabric, one cluster.
256 GPUs and moreThirty-two nodes and up
A row of racks, no special cooling.

Specifications

8Hopper GPUs, one NVLink domain
1.1 TBHBM3e, 141 GB per GPU
7.2 TB/sNVLink bandwidth in the node
10 kWper node, air cooled
GPUs
8 Hopper per node
GPU memory
1.1 TB, 141 GB HBM3e per GPU
NVLink
900 GB/s per GPU, 7.2 TB/s in the node
CPUs
2 x86 CPUs
System memory
1.5 TB or more
Networking
BlueField-3 SuperNICs, up to 400 Gb/s per GPU
Power
About 10.2 kW per node; up to 700 W per GPU
Cooling
Air
Fabric at Fulmis
InfiniBand or Spectrum-X Ethernet, sized to the workload
Software
Slurm and managed Kubernetes
Location
A data centre in the Santiago Metropolitan Region
Available
Q1 2027

Performance

Per node, as NVIDIA publishes it.

FP8 Tensor, per GPU
3,958 TFLOPS
FP16 / BF16 Tensor, per GPU
1,979 TFLOPS
TF32 Tensor, per GPU
989 TFLOPS
GPU memory
1.1 TB HBM3e, 4.8 TB/s per GPU
NVLink bandwidth
7.2 TB/s
Max GPU power
Up to 700 W per GPU, configurable
Node power
About 10.2 kW

NVIDIA's published figures. Tensor Core numbers carry sparsity unless the row says dense; H100, H200 and RTX PRO figures are per GPU because NVIDIA publishes no node total. Power figures are the ones we reserve and protect to, with NVIDIA's own where it publishes one.

How we deploy it

HGX H200 is the eight-GPU Hopper node with the larger HBM. It is air cooled at about 10 kW, which places one node per rack in an existing Santiago hall with no special cooling, and it is the platform for a team whose data has to stay in Chile and whose workload fits in eight GPUs.

A node is the smallest unit. It is sold on the same three to five year contract as every other platform.

Fulmis places the purchase order, or takes delivery of the fleet you already own. Either way we bring it into Chile, commission it against the vendor baseline and operate it for the term. You reserve the capacity, or your own hardware; the workload and the data stay yours.

Terms

Term
Three to five years
Price
Fixed for the term, in the term sheet
Commitment
Take-or-pay
Prepayment
None to 25% at signature
Smallest block
One node, 8 GPUs
Start
Q1 2027, first slot

Other platforms

PlatformGPUsGPU memoryNVLinkPowerCoolingSmallest blockAvailable
GB300 NVL72Rack scale 72per rack 20 TB288 GB per GPU 130 TB/s1.8 TB/s per GPU 132 to 140 kW155 kW peak Liquid 1 rack, 72 GPUs Q1 2027
GB200 NVL72Rack scale 72per rack 13.4 TB186 GB per GPU 130 TB/s1.8 TB/s per GPU 120 to 132 kWper rack Liquid 1 rack, 72 GPUs Q1 2027
HGX B3008-GPU node 8per node 2.3 TB288 GB per GPU 14.4 TB/s1.8 TB/s per GPU About 14 kWper node Air or liquid 1 node, 8 GPUs December 2026
HGX B2008-GPU node 8per node 1.4 TB180 GB per GPU 14.4 TB/s1.8 TB/s per GPU About 14.3 kWper node Air or liquid 1 node, 8 GPUs December 2026
HGX H1008-GPU node 8per node 640 GB80 GB per GPU 7.2 TB/s900 GB/s per GPU About 10.2 kWper node Air 1 node, 8 GPUs Q1 2027
RTX PRO 6000 Blackwell8-GPU node 8per node 768 GB96 GB per GPU PCIe Gen 5no NVLink 5.4 to 6.7 kWper node Air 1 node, 8 GPUs Q1 2027
Vera RubinRack scale 72per rack HBM4not yet published Not published Not published Liquid 1 rack On request