NVIDIA GB200 NVL72

The first rack-scale Blackwell system. Same 72-GPU NVLink domain, lower power.

  • 72 GPUs per rack
  • 13.4 TB GPU memory
  • Liquid cooled rack
  • Available Q1 2027

Configurations

Pick the footprint that fits. Every one is sold on the same contract.

72 GPUsOne rack
One NVLink domain. The smallest unit.
144 to 792 GPUsTwo to eleven racks
Joined by an InfiniBand or Spectrum-X fabric.
864 GPUsA full hall
Twelve racks in one existing Santiago hall.

Specifications

72Blackwell GPUs, one NVLink domain
13.4 TBHBM3e across the rack
130 TB/sNVLink bandwidth in the rack
17 TBLPDDR5X on 36 Grace CPUs
GPUs
72 Blackwell per rack
GPU memory
13.4 TB, 186 GB HBM3e per GPU
NVLink
1.8 TB/s per GPU, 130 TB/s domain
CPUs
36 Grace, 2,592 Arm cores
System memory
17 TB LPDDR5X
Networking
ConnectX-7, 400 Gb/s per GPU; BlueField-3
Power
120 to 132 kW
Cooling
Liquid cooled rack
Fabric at Fulmis
InfiniBand or Spectrum-X Ethernet, sized to the workload
Software
Slurm and managed Kubernetes
Location
A data centre in the Santiago Metropolitan Region
Available
Q1 2027

Performance

Per rack, as NVIDIA publishes it.

FP4 Tensor, dense
720 PFLOPS
FP8 / FP6 Tensor, dense
360 PFLOPS
FP16 / BF16 Tensor
360 PFLOPS
TF32 Tensor
180 PFLOPS
GPU memory
13.4 TB HBM3e, 576 TB/s
Fast memory, GPU and CPU
30 TB
NVLink bandwidth
130 TB/s
Scale-out network
ConnectX-7, 400 Gb/s per GPU
Rack power
120 to 132 kW; NVIDIA's rack guide says about 120 kW

NVIDIA's published figures. Tensor Core numbers carry sparsity unless the row says dense; H100, H200 and RTX PRO figures are per GPU because NVIDIA publishes no node total. Power figures are the ones we reserve and protect to, with NVIDIA's own where it publishes one.

How we deploy it

GB200 NVL72 is the first-generation rack-scale Blackwell system, with the same 72-GPU NVLink domain as GB300 and a lower power draw. It is the right platform where a workload is already tuned to Blackwell and the Ultra memory is not needed.

A rack is the smallest unit. We quote it in racks, with the fabric, storage and software sized to the cluster you describe.

Fulmis places the purchase order, or takes delivery of the fleet you already own. Either way we bring it into Chile, commission it against the vendor baseline and operate it for the term. You reserve the capacity, or your own hardware; the workload and the data stay yours.

Terms

Term
Three to five years
Price
Fixed for the term, in the term sheet
Commitment
Take-or-pay
Prepayment
None to 25% at signature
Smallest block
One rack, 72 GPUs
Start
Q1 2027, first slot

Other platforms

PlatformGPUsGPU memoryNVLinkPowerCoolingSmallest blockAvailable
GB300 NVL72Rack scale 72per rack 20 TB288 GB per GPU 130 TB/s1.8 TB/s per GPU 132 to 140 kW155 kW peak Liquid 1 rack, 72 GPUs Q1 2027
HGX B3008-GPU node 8per node 2.3 TB288 GB per GPU 14.4 TB/s1.8 TB/s per GPU About 14 kWper node Air or liquid 1 node, 8 GPUs December 2026
HGX B2008-GPU node 8per node 1.4 TB180 GB per GPU 14.4 TB/s1.8 TB/s per GPU About 14.3 kWper node Air or liquid 1 node, 8 GPUs December 2026
HGX H2008-GPU node 8per node 1.1 TB141 GB per GPU 7.2 TB/s900 GB/s per GPU About 10.2 kWper node Air 1 node, 8 GPUs Q1 2027
HGX H1008-GPU node 8per node 640 GB80 GB per GPU 7.2 TB/s900 GB/s per GPU About 10.2 kWper node Air 1 node, 8 GPUs Q1 2027
RTX PRO 6000 Blackwell8-GPU node 8per node 768 GB96 GB per GPU PCIe Gen 5no NVLink 5.4 to 6.7 kWper node Air 1 node, 8 GPUs Q1 2027
Vera RubinRack scale 72per rack HBM4not yet published Not published Not published Liquid 1 rack On request

Reserve GB200 NVL72