NVIDIA HGX B300

Eight Blackwell Ultra GPUs in a node. Air or liquid cooled, from one node up.

  • 8 GPUs per node
  • 2.3 TB GPU memory
  • Air or liquid
  • Available Q1 2027

Configurations

Pick the footprint that fits. Every one is sold on the same contract.

8 GPUsOne node
The smallest unit. Air cooled, in an existing Santiago data centre, live from December 2026.
16 to 248 GPUsTwo to thirty-one nodes
One InfiniBand or Spectrum-X fabric, one cluster.
256 GPUs and moreThirty-two nodes and up
A row of racks, four air-cooled nodes per rack in NVIDIA's reference.

Specifications

8Blackwell Ultra GPUs, one NVLink domain
2.3 TBHBM3e, 288 GB per GPU
14.4 TB/sNVLink bandwidth in the node
800 Gb/sscale-out per GPU, ConnectX-8
GPUs
8 Blackwell Ultra per node
GPU memory
2.3 TB, 288 GB HBM3e per GPU
NVLink
1.8 TB/s per GPU, 14.4 TB/s in the node
CPUs
2 x86 CPUs
System memory
2 TB or more
Networking
ConnectX-8, 800 Gb/s per GPU; BlueField-3
Power
About 14 kW per node (NVIDIA DGX B300 figure); air cooled at four nodes per rack, about 56 kW, in NVIDIA's reference
Cooling
Air or liquid
Fabric at Fulmis
InfiniBand or Spectrum-X Ethernet, sized to the workload
Software
Slurm and managed Kubernetes
Location
A data centre in the Santiago Metropolitan Region
Available
From December 2026

Performance

Per node, as NVIDIA publishes it.

FP4 Tensor, dense
108 PFLOPS
FP8 / FP6 Tensor
72 PFLOPS
FP16 / BF16 Tensor
36 PFLOPS
TF32 Tensor
18 PFLOPS
GPU memory
2.3 TB HBM3e, 64 TB/s
NVLink bandwidth
14.4 TB/s
Scale-out network
1.6 TB/s, ConnectX-8
Node power
About 14 kW (NVIDIA DGX B300)

NVIDIA's published figures. Tensor Core numbers carry sparsity unless the row says dense; H100, H200 and RTX PRO figures are per GPU because NVIDIA publishes no node total. Power figures are the ones we reserve and protect to, with NVIDIA's own where it publishes one.

How we deploy it

HGX B300 is the eight-GPU Blackwell Ultra node. It is the platform for a fleet that is served and scaled node by node rather than as one NVLink domain, and it is available air cooled, which widens where it can be placed.

A node is the smallest unit. Clusters are built with an InfiniBand or Spectrum-X Ethernet fabric, sized to the workload, under Slurm or managed Kubernetes.

Fulmis places the purchase order, or takes delivery of the fleet you already own. Either way we bring it into Chile, commission it against the vendor baseline and operate it for the term. You reserve the capacity, or your own hardware; the workload and the data stay yours.

Terms

Term
Three to five years
Price
Fixed for the term, in the term sheet
Commitment
Take-or-pay
Prepayment
None to 25% at signature
Smallest block
One node, 8 GPUs
Start
Q1 2027, first slot

Other platforms

PlatformGPUsGPU memoryNVLinkPowerCoolingSmallest blockAvailable
GB300 NVL72Rack scale 72per rack 20 TB288 GB per GPU 130 TB/s1.8 TB/s per GPU 132 to 140 kW155 kW peak Liquid 1 rack, 72 GPUs Q1 2027
GB200 NVL72Rack scale 72per rack 13.4 TB186 GB per GPU 130 TB/s1.8 TB/s per GPU 120 to 132 kWper rack Liquid 1 rack, 72 GPUs Q1 2027
HGX B2008-GPU node 8per node 1.4 TB180 GB per GPU 14.4 TB/s1.8 TB/s per GPU About 14.3 kWper node Air or liquid 1 node, 8 GPUs December 2026
HGX H2008-GPU node 8per node 1.1 TB141 GB per GPU 7.2 TB/s900 GB/s per GPU About 10.2 kWper node Air 1 node, 8 GPUs Q1 2027
HGX H1008-GPU node 8per node 640 GB80 GB per GPU 7.2 TB/s900 GB/s per GPU About 10.2 kWper node Air 1 node, 8 GPUs Q1 2027
RTX PRO 6000 Blackwell8-GPU node 8per node 768 GB96 GB per GPU PCIe Gen 5no NVLink 5.4 to 6.7 kWper node Air 1 node, 8 GPUs Q1 2027
Vera RubinRack scale 72per rack HBM4not yet published Not published Not published Liquid 1 rack On request